Set came in with shorted hor output transistor. Standby B+ is 180volts. Other supply voltages close to normal. With 60watt bulb for load the B+ is 142.5volts.



Answers :

\015\012\015\012\015\012\015\012\015\012\015\012\015\012\015\012\015\012"Set came in with shorted hor output transistor. Standby B+ is 180volts. Other supply voltages close to normal. With 60watt bulb for load the B+ is 142.5volts." (sic)Before anything can be done, one must know the make model number and chassis number of the unit in question before anyone could even make a rudimentary conclusion. This above makes little sense out of context.\015\012\015\012and well while I applaud you for wanting to have a go and try to repair you set. But PLEASE, start in the right place, otherwise you will simply waste your time and money, You see, you MUST start, in the right place, The power supply, FIRST, as, if, that isn't right, nothing else can be. But you simply cannot do anything without a Service Manual. In this it has everything one needs to repair the set. OK if it is shutting down, after that amount of time, of working and then faulting, then it is most definitely a "Thermal" problem, the way we "Find" problems such as this is "Freeze Spray" you use this on each component that is suspected of being the "Culprit" and you will soon,find that errant component. Now, also not every fault is a Capacitor, I see many, many people that think, that Capacitors are always the "Culprit" and replace them, because someone else had done so and it worked, well that maybe sometimes true, but most Symptoms, can, and do have many, many different "Causes" & also, now while that may be true in a few cases, a faulty Electrolytic Cap, or even, ordinary, Cap goes faulty, this is only a SYMPTOM, something has damaged those caps causing them to "Fail". One MUST always find the root "Cause", otherwise if you just treat, the SYMPTOM, the "Cause" will just make the "Symptom" come back, in short order, as the prime cause still, hasn't been fixed., Now Capacitors hate AC ripple, or Over Voltage. That's it. Oh.. and Heat, if these Capacitors, are too close to a Heat Source, then thats a prime cause of failure. Resistors, hardly ever go faulty,and if they do, it is generally obvious. However it doesn't hurt to check values with our Multimeter. Remember though resistors are made, with up to 20% tolerance from stated value, as such, are not too critical, unless in Timing circuits etc. Always check, the Values, of resistors, as with any other component, with the power OFF. Now Diodes especially "Zener Diode", are another thing to check, those and ordinary "Signal Diode" should always be suspect. next we have Transistors and IC's. The Transistors MUST ALL be checked to see if they have a good, "Junction" this is done, with our meter set to "Diode Test" and usually are about 0.6 to 0.7. With IC's you must check, voltage levels, or Logic Levels, going in and out, have a look at the circuit diagram, and it will tell you what they should be. It is a good idea to always measure the Power Supply voltages, see if a "Rail" is Low, that will be because some component has gone somewhat or all short circuit, to Earth, now, if the "Rail" is Higher, suspect an "Open Circuit" component, like a Diode, or Transistor. The voltages expressed in the manual are spot on, ANY variation MUST be investigated. I have been doing all this for over 30 years now, and I do indeed wish, we could have a set of "Symptoms" and be ables to say.. "Oh that;s the so-in-so and replace this" however unfortunately this although does happen, most "Symptoms" can have literally tens, of "Causes" all often "Interlinked" One simply has to do a methodical troubleshooting procedure, and always think, "are my Voltages Correct" as this is how, you Fix the problem, by making them so. Keep up the good work. You MUST get a Service manual, it is imperative you get one, even if you must pay for it. It will pay for itself in about 2 mins.
What is the brand and model of your TV is it an ordinary CRT TV?

Causing the horizontal output transistor to be shorted.
1.deflection yoke is leak -you can visually check the yoke ..spot for a burned magnetic wire winding.
2.bad plyback transformer-not oscillating plyback with internal arching of high voltage
3.leak high voltage capacitor..replace bulging capacitors from high voltage.
4.use original transistor only a generic china made transistor heats up faster and dont last.

Repair Help & Product Troubleshooting for Flat Panel Televisions
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

Set came in with shorted hor output transistor. Standby B+ is 180volts. Other supply voltages close to normal. With 60watt bulb for load the B+ is 142.5volts.


\015\012\015\012\015\012\015\012\015\012\015\012\015\012\015\012\015\012"Set came in with shorted hor output transistor. Standby B+ is 180volts. Other supply voltages close to normal. With 60watt bulb for load the B+ is 142.5volts." (sic) ... Flat Panel Televisions

I bought a new LG LED TV 32LV375G and connected it up. After 2 days working fine it began to switch off after approx 5 mins operating. I measured the mains voltage and found it 249volts. I called the electricity provider and they came to change the supply to another phase with lower voltage. It worked fine for 4 months and repeated the problem last week. I quickly measured the mains voltage and found it 244volts. I took it to a technician and was told that everything is fine with the tv. I g


... LG Flat Panel Televisions

I have Hitachi 65f710 projection tv, that has no power, I found a thermal fuse open in the power supply, I replaced that; the Tv came on but has no hi voltage, the tv has b+ but not at HOT hight voltage transistor. what else you think can be done. Right now I have no picture Thanks


Try replacing the H-out transistor, if yours is convergence IC type, replace it. hope this help, please rate and vote. ... Hitachi 57F500 57" Rear Projection HDTV-Ready Television

My Cyberpower CPS 1200 EI LCD Inverter output voltage is176V and varies with load and there are some times charging problems.


... Flat Panel Televisions

Looking for a replacement lamp also. one said to check bulbtogo but they dont have them and it seems like nobody else does either. wondered if anyone had any luck after posting that they couldnt find one. does anyone know what the voltage and wattage is for this lamp. i guess if all else fails i could try to remove the bulb itself and replace it with something close. that or im out a $9,000 TV...


Mats Electronics Sales Lamps for $89.00- $139.00 1-800-628-1118\012Lamp PN# 915PO16010\012Look on EBay under Electronics TV/Parts type in Lamp number. ... Mitsubishi WL-82913 82" Rear Projection HDTV

I have a Samsung PS50Q97HD plasma TV that keeps blowing new boards and I don't know why. It came to me with a faulty YSUS that had damaged the VS supply section in the PSU board. I fixed the PSU and fuse and have good VS voltage now. I replaced the YSUS main. I powerd the TV and the upper YDRIVE (Yscan buffer) board chips when pop. I put this down to it getting damaged unseen when the YSUS went faulty. I replaced the YDRIVE upper with new and then the lower board went faulty too (holes blew in t


... Samsung Flat Panel Televisions

I have A Samsung 52 inch LCD TV model #LN52A580P6FXZA. The relay clicks at A random rate, there is A red light that flashes steady. It will not power up. All my standby voltages coming from the power supply are present as well as the run voltages. Power supply on voltage is present, inverter on voltage is present, occasionally, it will give A loud high pitched squeal. It never comes on. Any help would be appreciated.


... Flat Panel Televisions

Panasonic TC-P50C2 won't turn on, no red stand by light, can hear a "buzz" when you get close to the power supply board.


... Panasonic TCP50C2 50 in. TV

Hi, I have a Sanyo 50" DP50740 and need a dual voltage power supply put in or at least a 220volt power supply. What power supply do recommend and where can i get it since Sanyo only sells to authorized repair shops. thanks.


... Sanyo DP50747 50 in. Plasma TV

W/supply voltage fuse is ok w/output voltage no supply voltage on fly back


Try this steps\012\0121. check the voltage across the 160v usually 100uf electrolytic cap.\012\011if you have a B+ here then you have a open fusible resistor in line with the B+.\0122. If there is no B+ on the cap, you have a probl ... Flat Panel Televisions

I have a TH50PX60U with the red light flashing 10 times. I went through the diagnostic flow chart to where it said replace the PA and DG boards. I replaced both and still have the 10 flashing lights. SInce that flow chart didn't seem to work I started checking the feeds from the power supply. I noticed on the PA10 that as soon as I plugged in the AC, the voltage read 15V. Then the voltage started dropping fast and went down to zero. Is this normal or should the voltage remain at a cons


... Panasonic TH-50PX60U 50 in. Plasma HDTV

Sony KDS-55A2000. bought 1/07. replaced bulb 2/08. gave tv to parents 11/10. worked fine until last week. 1 on screen message, temperature warning (they checked all vents-everything clear and 1' away from wall) then lamp going out message came across. red light blinked 4x and powered off. I ordered new lamp assy came in mail today. parents installed. green light came on then red light blinked 4x-nothing. parents don't have extra income and my financial help is limited. any easy fix solutions????


You will need to check the fans are all switching on when you turn the tv on, it might be one of the fan sensors that has gone bad, the tv wont turn on if it detects that the fans or a single fan is not working. I have not worked on this particular s ... Sony KDS55A2000 55" HDTV

Samsung dlp hls4666wx TV. After a power surge, my TV shuts off after about 4 minutes. The stand by, TV, timer lights flash...manual says it's the bulb or fan. Only, I bought a new bulb, and noticed both fans are working. Still does it. It makes a small pop them hiss or buzz sound when it offers the bulb down. The power supply and ballast look ok (circuit boards). Perfect picture and sound before shutting down. I've heard there are 3 fans but only see two. Could it be another fan I don't see? Or


... Projection Televisions

I have 6 gp328 and my multi charger power supply burned i guess due to the variying of frequency, can i use diffrent power supply with the same output voltage of the burned power supply?


Yes,,the same input,output and also wattage.. ... Flat Panel Televisions

My hitachi 29in ctv power supply 110vac had a problem on zener diode will blown if we switch on the tv. what spare parts to change so that the power supply zener diode will not blown again and the supply voltage remain in normal condition.


The secondary output voltage comes out from is more than it should be there. That is why, the protection zener diode blows off, as soon as you switch ON the set. First find and repair the power supply regulator, for correct output voltage. Refer i ... Hitachi Standard (CRT) Televisions

55HDS52 no picture no sound. no startup voltage on vsago and vcego connector on connector CN68 power supply and logic board was replaced and still no voltage. what create the 3.15 voltage on pin 2 and 3 for cn68 connector.


... Hitachi Flat Panel Televisions

When power supply to TV exceeds 224V the TV switch off. It then tries to switch "on" again and will do so until the power supply to TV is lower than 224V. I ran a AC DC regulater to keep power output to TV as close to 220V. Then TV plays perfect. Aventually I unplug TV and go to bed. I have tried UPS's as well. Same problem. I think power supply unit in TV is damaged due to power surges. I replaced this 2 year old TV with a new one. Costly excercise. I still belive this TV can be fixed.


If a power supply is what you want, they are available all over the world, just use the internet like you did tonight and use Google, type in your tv make and model and power supply and you will find them. Parts are really hard to come by now the Qua ... Flat Panel Televisions

No Vs Voltage (200-210) out of a BN44-175A Samsung Power supply


If no voltage out either a short on the line pulling it down or its at the source--usually one or the other. ... Toshiba Satellite Flat Panel Televisions

Required output voltages from an acoustic solution lcd television power supply unit


Only the original supply is going to work---schematics with voltages and wave forms are rarely available online except to a authorized service center for that brand---they want to SELL REPLACEMENT boards and not have someone fix them. ... Flat Panel Televisions

DP46849 Sanyo. I have checked all of fixya for solutions. I hane no sound or screen but have a green light when turned on. It will flash as if it is in protect mode. I have checked voltage and there seems to be 5v, 12v and 15v as indicated on power supply. I cannot find a 24v to read from but I did pull the master inverter to see if I had sound. Still the green light flashes and no sound. I suspect power supply only because when it is turned off I hear a high pitched whistle that slowly goes on


Hi,Power supply board seems defective and causing problem. Please replace power supply board to solve tv issue, required board is available in ... Flat Panel Televisions

I have a Power Supply Unit in Westinghouse SK-26H240S TV. TV had no power prior to disassembly. This TV has the Delta DPS-210EP-2 power supply. I appear to have proper voltage on high side, but i am not getting 24v; 12v; 5v, and 5VSB on secondary side output. The Bridge Rectifier is putting out 53V DC. The filter caps have been replaced on PSU.


... Westinghouse LTV-27w7 7 in. LCD HDTV

I have a sansui platinum plus 27" tv and it has no manula controls for the closed captioning. the closed captioning came on and will not go off. the tv is approx. 6 years old.


... Sansui 27" TV

My tv has dark picture. The fuse keeps popping on the zsus board on my lg flatron ru-42px10. I checked the output voltage from the power supply vs-350v, va-95v. I know there's something wrong on the power supply but what? Can you help me?


... LG RU-42PX10 42 in. HD-Ready Plasma Television

I have anew Sony 40 inch EX 520 series Led warranty not valid in India since purchased in Bangkok. The power standby light goes of very often and the Tv goes dead. If I switch off the power supply for couple of minutes and switch it on again the stand by light comes back on and TV functions normally. The TV is also very sensitive to voltage fluctuations and on Inverter power supply. Please let me know what could be wrong and how to solve this problem. Thanks


... Flat Panel Televisions

Sansui SV-3715LCD, I switch off the unit at the wall socket, when I plugged it in the next day there was no power, not even the LED indicator light on the front of the LCD activates. I checked the plug power and it has AC supply voltage right up onto the internal Switch-mode power supply board. Any suggestions


Continue to check--every set has a standby power supply that powers the remote circuit to turn set on and it runs 7/24 if set is plugged in.Never a good idea to turn set of by taking the AC away--it can cause micro problems(micro processor). ... Flat Panel Televisions